Tiltmeter
The Tiltmeter page is used to set the conditions in which the receiver will communicate with and get information from the tiltmeter.
For each serial port (A, B, F), the following parameters can be set to allow a connection to the tiltmeter:
Parameter |
Designation |
$PASHS |
Process tiltmeter |
Enable this option to allow the receiver to query the tiltmeter, if connected to this port. |
TLT |
Baud Rate |
Set the port baud rate |
PRT |
Mode |
Set the port mode (RS232 or RS422). Only port A can be RS422 or RS232. All the others are necessarily RS232. |
MDP |
RTS/CTS |
Enable or disable the handshaking protocol on this port. |
CTS |
Initialization string |
Define the string used by the receiver to initialize the tiltmeter, if connected to this port. |
TLT |
Trigger string |
Define the string used by the receiver to query the tiltmeter, if connected to this port. |
TLT |
Interval |
Set the time interval, in seconds, used by the receiver to query the tiltmeter, if connected to this port. |
TLT |
Data format:
Parameter |
Designation |
$PASHS |
“Legacy D-File Support” check box |
Tiltmeter data are part of the data saved in G-files. If you check this option, they will also be saved as separate D files (Ashtech legacy format). |
RFT |